Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
GTAKE brand ac motor drive / frequency inverter
Prev
GTAKE brand ac motor drive / frequency inverter
Next

GTAKE brand ac motor drive / frequency inverter

FOB Price

Get Latest Price

60 ~ 10000 / Piece

|

1 Piece Minimum Order

Country:

China

Model No:

as model

FOB Price:

60 ~ 10000 / Piece Get Latest Price

Place of Origin:

-

Price for Minimum Order:

60 per Piece

Minimum Order Quantity:

1 Piece

Packaging Detail:

carton

Delivery Time:

3-35days

Supplying Ability:

10000 Piece per Month

Payment Type:

T/T, L/C, Western Union

Product Group :

Contact Now
Free Member

Contact Person jessica

tangtou, Shenzhen, Guangdong

Contact Now

Product Specification

  • Input terminals:DI-7(HDI-1), AI-3 0~10V, or 0-20mA
  • Certificate:CE, GOST, ISO9001:2008
  • Applying motor:Asynchronous motor and synchronous motor
  • IP grade:IP20
  • Output terminals:DO-2(HDO-1), RO-2, AO-2

Product Description

Technical Features of GK**0 Series Mini AC Motor Drives

Power Rated voltage *-phase **0VAC~**0VAC; *-phase **0VAC~**0VAC;
single phase **0VAC~**0VAC 
 
Rated current See the table "Model information of GK**0 series"  
Frequency *0Hz/*0Hz, tolerance ±5%  
Allowable range of voltage Voltage consecutive fluctuation ±*0%, short fluctuation **5%~**0%  
Voltage out-of-balance rate <3%,THD meets standard IEC******2  
Power output Applicable motor (kW) See the table "Model information of GK**0 series"  
Rated current (A) See the table "Model information of GK**0 series"  
Output voltage (V) *-phase: 0~ rated voltage, error < ±3%  
Output frequency (Hz) 0.*0~ **0.*0Hz; unit: 0.*1Hz  
Overload capacity **0% - 1min; **0% - *0s; **0% - 0.5s, once per *0 mins  
Control characteristics V/f patterns  V/f control  
Sensor-less vector control 1  
Sensor-less vector control 2  
Range of speed regulation 1:**0 ( V/f control, sensor-less vector control 1)  
1:**0 (sensor-less vector control 2)  
Speed accuracy ±0.5% (V/f control)  
±0.2% (sensor-less vector control 1 & 2)  
Speed fluctuation  ±0.3% (sensor-less vector control 1 & 2)  
Torque response < *0ms (sensor-less vector control 1 & 2)  
 
Starting torque 0.5Hz: **0% (V/f control, sensor-less vector control 1)  
0.*5Hz: **0% (sensor-less vector control 2)  
Basic functions Start frequency 0.*0~ **0.*0Hz  
Accel/Decel time 0.*0~****0s  
 
Carrier frequency 0.7kHz~*6kHz  
Frequency setting sources Digital setting + keypad/  
Digital setting + terminal UP/DOWN  
Communication   
Kaypad POTanalog  
Terminal pulse setting  
Motor started methods Started from starting frequency  
DC braking and then started  
Flying start  
Motor stopped methods Ramp to stop  
Coast to stop  
DC injection braking at ramp stop  
Dynamic braking capacity Rated voltage **0V: Braking unit triggered voltage: **0V~**0V; service time: 0.0~**0.0s;
Rated voltage **0V: Braking unit triggered voltage:**0V~**0V; service time: 0.0~**0.0s; 
 
DC braking capacity DC braking start frequency: 0.*0~**0.*0Hz  
DC braking current: 0.0~**0.0%  
DC braking time: 0.0~*0.*0s  
Input terminals Four digital s; One analog , voltage/current programmable  
 
Output terminals  One digital output, one relay output; and one analog output (voltage/current programmable), can output signals such as command frequency, or output frequency, etc.  
 
 
 
Featured functions Various master & auxiliary command and switch over, flying start, a variety of Accel/Decel curves programmable, automatic correction of analog, *-step speed control programmable (*-step support flexible frequency command), three faults recorded, over excitation brake, over voltage stall protection programmable, under voltage stall protection programmable, restart upon power loss, skip frequency, frequency binding, four kinds of Accel/Decel time, process PID control, asynchronous motor parameters autotune, field-weakening control, precision torque control  
Protection functions Refer to Chapter *- Troubleshooting  
Environment Place of operation Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop or salt, etc.  
Altitude 0~***0m  
De-rate 1% for every **0m when the altitude is above ***0 meters  
Ambient temperature  **0~*0
*0~*0: rated output current de-rates 1% for every 1above *0 
 
Relative humidity 0~*5%, no condensation  
Vibration Less than 5.9m/s2 (0.6g)  
Storage temperature **0~**0  
Others Installation  Wall-mounted  
IP grade IP*0   
Cooling method    Forced air cooling  
 
j! <0HF**4 style='width:**3.*5pt;border-top:none;border-left:none; border-bottom:solid #A5A5A5 1.0pt;border-right:solid #A5A5A5 1.0pt; padding:0cm 5.4pt 0cm 5.4pt;height:*0.0pt'>Seven digital terminals, one of which can be used for high-speed pulse . Compatible with active open collectors NPN, PNP and dry contact
Three analog terminals, one of which can be only used as voltage , while the other two are optional for voltage/current.
Output terminals
One high-speed pulse output terminal, 0~*0kHz square wave signal output; can output values, such as setting frequency and output frequency, etc.
Two relay output terminals
Two analog output terminal, voltage/current output optional; can output values, such as setting frequency and output frequency, etc.
Encoder signal terminal
Compatible with 5V/*2V encoder
Compatible with different types of encoder signal , such as open collector, pushpull and differential, etc.
Characteristics
Parameter copy, parameter backup, common DC bus, free switching between parameters of two motors, flexible function code displayed & hidden, various main & auxiliary settings and switchover, reliable speed search started, various acceleration & deceleration curves options, automatic correction of analog value, brake control function, **-step speed programmable(*-step speed supports flexible frequency setting), swing frequency control operation, fixed-length control, counting function, three fault recorded, over excitation brake function, over-voltage stall prevention, under-voltage stall prevention, restart upon power off selectable, hopping frequency function, frequency binding function, free switch between four-segment acceleration/deceleration time, motor thermal protection, flexible fan action control, process PID control, simple PLC control, flexible multi-functional key setting, droop control, parameter identification of asynchronous and synchronous motors, weak magnetic control, high-precision torque restraint, V/f separated control, torque control without PG, torque control with PG, two encoder signal s (supporting incremental, UVW hybrid and rotating transformer, and other speed feedback modes), flexible deceleration ratio control, zero servo, main axis orientation, simple feed forward control, pulse train position control
Protection functions
Refer to Chapter VII - Fault Diagnosis and Abnormality Handling
 

Country: China
Model No: as model
FOB Price: 60 ~ 10000 / Piece Get Latest Price
Place of Origin: -
Price for Minimum Order: 60 per Piece
Minimum Order Quantity: 1 Piece
Packaging Detail: carton
Delivery Time: 3-35days
Supplying Ability: 10000 Piece per Month
Payment Type: T/T, L/C, Western Union
Product Group : GK500 series

Send a direct inquiry to this supplier

To:

jessica < Jiangsu Gtake Electric Co., Ltd. >

I want to know: